- Quality of the measurement data is high.
- Origin of the data is Ascend Acoustics.
- Format of the data is a set of 36 horizontal and 36 vertical measurements .
-
Sensitivity:
- Company: 82.0 dB
- Measured: 80.1 dB (avg. 300Hz-3kHz for 2.83V measured at 1m).
- -3dB (resp. -6db) point v.s. reference is at 74.7Hz (resp. 58.6Hz).
- Reference level is normalised to -0.1dB computed over the frequency range [300.0Hz, 5000.0Hz].
- Frequency deviation is 2.3dB over the same frequency range.
- Tonality (Preference) Score
- Tonality (Preference) Score is 4.99
and would be 7.61 with a
perfect subwoofer.
- Details: NBD: ON 0.447, LW 0.351, SP 0.386, PIR 0.341; SM: SP0.933, PIR0.89; LFQ 0.689, LFX 58Hz
- Tonality (Preference) Score is 6.29
with an EQ and would be 8.48 with a
perfect subwoofer and the same EQ.
- Details: NBD: ON 0.309, LW 0.204, SP 0.26, PIR 0.203; SM: SP0.949, PIR0.94; LFQ 0.617, LFX 46Hz
- Tonality (Preference) Score is 4.99
and would be 7.61 with a
perfect subwoofer.